November 18, 2026 · 5 min read
PIPESIM automation: the checks matter more than the runs
Running 200 cases is the easy part. Trusting 200 results is where network studies actually lose time.
A network study for a brownfield tie-in or a field-life review rarely has fewer than 50 cases. Field-life years, water cut, GOR, arrival pressure and flow multiply quickly: nine years × six water cuts × two arrival pressures is already 108 cases before anyone asks for a sensitivity. Engineers set these up by hand, run them, paste results into Excel and check velocities line by line. Three to ten days later, a lead engineer reviews a workbook they cannot fully trace.
Automating the runs is the obvious fix, and it is not the hard part. The hard part is everything around the runs.
Lint the model before it runs 200 times
A mistake in the base model is copied into every case. Before running anything, check the model itself:
- Every source has a fluid assigned, and black-oil and compositional fluids are not mixed without intent.
- Pipe roughness is physically reasonable, and ambient temperature and heat-transfer data are present.
- Boundary conditions are neither over- nor under-specified for the network solver.
- There are no disconnected branches, zero-length or duplicate flowlines, or elevation profile jumps.
- Flow correlations are set, and consistent across lines in similar service.
Ten minutes of linting saves a night of runs.
Treat convergence as a result
A case that did not converge is not a case with bad numbers. It is a case with no numbers, and it is easy to miss when results are pasted into a spreadsheet that still shows the previous case's values. Every case needs a convergence status in the output, and every non-converged case needs to be flagged, not dropped.
Check every line, every case, against written criteria
The checks themselves are well known:
- Erosional velocity. API RP 14E gives
Ve = C / √ρmin field units (ft/s, lb/ft³). In SI that becomes roughlyVe = 1.22 × C / √ρmwith ρm in kg/m³. The C-factor is a project decision, so it belongs in the criteria, not in someone's head. - Velocity bands for liquid and gas, per service.
- Arrival pressure against the separator inlet requirement.
- Pressure drop per km, flagged against the client limit.
- Holdup and slugging, flagged for engineering judgement rather than pass/fail.
- Arrival temperature against the hydrate or wax limit for the study.
What makes them slow is doing them by hand across every line of every case. What makes them unreliable is that the criteria are not written down in one place.
Make the report traceable
A lead engineer signing a study needs to see what was run, what was checked, against which limits, and which cases failed. That means the case matrix, the criteria and the exceedance table belong in the report, not just the plots.
Drive the simulator, don't puppet it
SLB's PIPESIM Python Toolkit lets a script open a model, set case inputs, run simulations and read results without touching the user interface. That matters: screen automation breaks when a dialog moves, while a toolkit-driven run is repeatable. It also means the work can stay on the machine where PIPESIM is licensed, with the model file never leaving site.
Where this leaves the engineer
Automation does not remove the engineer from a network study. It moves them to the part that needs them: deciding the cases, setting the criteria and judging the exceedances. That is the idea behind PIPESIM Harness: lint, run, check and report, on your own licence, with the engineer confirming the case matrix before it runs and signing off the report after.
PIPESIM is a trademark of SLB. ignzai is not affiliated with SLB.